Automotic Power Factor Correction

Most of the industrial and Commercials installations have large variables inductive severe loads such as motors, CNC Machines, Air conditioners, Variable Frequency Drives, Thyristor Drives, etc. This results in lagging of Power factor. This means loss and wastage of Electrical resources and heavy Penalties by Electricity Board. In some cases such as fixed load system, manually operated capacitor banks are used but this is not correct solutions because chances of Switching ON and OFF are done by Operator.
However in case of rapidly varying and scattered loads it becomes difficult to maintain a high power factor by manually switching on/off the capacitors in proportion to variation of load within an installation. This drawback is overcome by using an APFC panel (Automatic Power Factor Correction Panel) which not only maintains a power factor but also eliminates the need for constant manual interference

Type KVA Ratings Model Servo Motor Input Voltage
Range (VAC)
Output Voltage
(VAC)
Single Phase 1 – 100KVA SD – XXX
SA – XXX
PMDC /
AC Synchronous
170 - 270 230

a) Please contact our sales and application engineers for further guidance
b) Non-Standard Input Voltage Range and Output Voltages are also available on request

Rating 30 – 1200 KVAR
Steps 2 / 3 / 5 / 6 / 10 / 12.5 / 20 / 25 / 30 / 40 / 50 / 60 / 75 / 80 KVAR
Sensing Single / Three CT Sensing.
PF Controller LCD Display for PF. LCD Display for PF & Power Parameters.
Incomer MCCB / ACB for Over load and short circuit protection.
Each Step Protection 1)HRC Fuse 2)MCB / MCCB
Detune Reactors Copper / Aluminum 1)Without 2) 1 % 3) 5.6 % 4) 7 % 5) 14 %
Capacitors MPP / Gas Field / APP 1)440 Volts. 2)525 Volts. 3)690 Volts
Contactor Switch 1)Capacitor duty contactor. 2)AC 3 Duty Contactor. 3)With Early make contact
Communication RS 485 / RS 232 Optional.
  • Medical Diagnostic Equipment
  • Electronic Equipment
  • Lab Equipment
  • Pharmaceuticals Machine
  • Textile Machinery
  • Process Controls
  • Elevators
  • Cold Storage
  • Hospitals
  • Residential
  • Step switching using Contactor Switching.
  • Reduction of voltage flickering.
  • Enhances capacity of Transformer, Local generator systems such as Diesel and windmill generator.
  • Saves energy by reduced max. Demand, PF bonus & saving in Transformer losses.
  • Accurate Power Factor control, even in the presence of Harmonics.
  • Dramatically increases the life expectancy of switching elements and capacitor.
  • Built-in network analyzer, measuring all network parameter including harmonics.
  • Modular and up gradable with increased plant load.
  • Detuned systems that detune the network to prevent resonance and absorb harmonics.
  • Ammeter for Load Current.
  • Input Under and Over Voltage indication and Cut off
  • Electronics Output Over Load.
  • Ground Fault Monitoring with Trip and Indication / Earth leakage.
  • Surge Suppressor (Metal Oxide Varistor)
  • Surge Protective Device 8/20 micro sec. as per IEC 61000-4-4 / 61000-4-5.
  • Stabiliser By pass Switch
  • Auto Start with time delay.