Furance Transformer - Induction & Melting

Furnace Transformers are used to supply power where there are high current requirements to electric furnaces of the induction, resistance, open arc, and submerged-arc types.
The secondary of furnace Transformers are generally low voltage are with high harmonics withstanding capacity.

Heating Steel Plant Rolling mills
Various Industries like mining, cement. Non Ferrous Metal Industries. Heavy Engineering
Parameter Description
KVA Rating – Three Phase 50 to 2500 KVA
Cooling Air & Oil Cooled.
Input Voltage 415 - 3 Phase or as required.
Output Voltage Up to 100 V or as required.
Construction Double wound, Common core, Varnish and vacuum impregnated.
Winding Electrolytic grade Copper
Frequency 50 +/- 3 Hz / 60 Hz on request.
Insulation Class / Level F Class / 155 deg. C & H Class / 180 deg. C
Maximum temperature rise 115 deg. C.
Efficiency Better than 97 %.
Regulation 2 – 4 % or as required.
Galvanic Insulation Better than 500 / 1000 Mega-Ohms - DC Isolation @ 2500 V
High Voltage Breakdown Test 2.5 KV for one Minute Between windings and Earth.
Termination Type Terminal Board / Stud – Bolts / Bus Bar
Enclosure Protection Class IP21 / As per Requirement.
Enclosure Finish Siemens Gray, RAL 7035 (Other color available on request).
Environment Temperature Range 0 to 45 °C. Suitable for indoor Tropical use 90% RH (non-condensing).
Reference Standard IS2026 / IS11171
Life Expectancy 25 Years
  • Medical Diagnostic Equipment
  • Electronic Equipment
  • Lab Equipment
  • Pharmaceuticals Machine
  • Textile Machinery
  • Process Controls
  • Elevators
  • Cold Storage
  • Hospitals
  • Residential
  • High Cross Section.
  • Use of Multi-stranded Copper conductor to reduce Eddy current losses.
  • Use of High permeability, low losses electrical steel.
  • Provide electrostatic earth shield between windings to protect rectifier elements against line voltage surges.
  • Cores designed for reduced flux densities to compensate for harmonic voltage distortion.
  • Very High currents as compared to Conventional transformers.
  • Large low voltage variation to suit furnace application.
  • Withstand harmonics generated due to rectifier, furnace operation
  • Ammeter for Load Current.
  • Input Under and Over Voltage indication and Cut off
  • Electronics Output Over Load.
  • Ground Fault Monitoring with Trip and Indication / Earth leakage.
  • Surge Suppressor (Metal Oxide Varistor)
  • Surge Protective Device 8/20 micro sec. as per IEC 61000-4-4 / 61000-4-5.
  • Stabiliser By pass Switch
  • Auto Start with time delay.

Typical schematics for product installation

  • # Non-Standard KVA, Input Voltage Range and Output Voltages are also available on request.
  • # NEELKANTH reserves the rights to amend design and specification without notice as continuous efforts are Made to Improve product performance.
  • # Some of the features are optional depend on model and as per order.